Standard

JIS G3457

JIS G3457--Arc welded carbon steel pipes.

This Japanese Industrial Standard specifies the arc welded carbon steel pipes (hereafter referred to as “pipes”) used for piping for steam, water, gas, air, etc. of comparatively low working pressure.

Elongation of pipes with a wall thickness under 8mm,tested using testpiece No.5(perpendicular to pipe axis direction)


Wall thickness

Over 5mm up to and

incl.6mm

Over 6mm up to and

incl.7mm

Over 6mm up to and

incl.7mm

Elongation

15min

16min

18min


Tolerances on outside diameter and wall thickness(Unit:%)

Item

Tolerance

Tolerance on outside diameter

±0.5

Tolerance on wall thickness

Nominal dimameter 450A or under

+15

-12.5

Nominal diameter over 450A

+15

-10

Notes

a)In this case,either the actually measured value of circumfential length or outside diameter and the

circumferential length or outside diameter obtained by conversion thereof shall be used.

The mutual conversion of the outside diametre and the circumferential length shall be made by the following

equation.

D=l/π

Where,D:outside diameter(mm)l:circumferential length(mm)

π:3.1416

b)For the local parts such as repaired parts,the outside diameter tolerances in this table shall not apply.





Chemical composition

Symbol of grade

C

P

S

STPY400

0.25max

0.040max

0.040max


Mechanical properties

Symbol of

grade

Base metal

Tensile

strength

of weld






N/mm²

Tensile strength





N/mm²

Yield point or proof stress





N/mm²

Elongation%

Tensile test

piece

Tensile test direction

Test piece

No.5

Perpendicular to pipe axis

direction a)

STPY 400

400min

225min

18min

400min

NOTE :1N/mm²=1MPA

Note :a) A test piece,when taken from the steel strip or steel plate,shall be either in

parallel to or perpendicular to the rolling direction.